Saturday, December 14, 2019
Gas Turbine Free Essays
Types of ventilation ââ¬â Induced draft ventilation ââ¬â Turbine ,Acc module ââ¬â Positive ventilation- LGB, Exhaust Ventilation System Design features â⬠¢ Induced Draft Ventilation â⬠¢ Number of compartments â⬠¢ Accessory compartment â⬠¢ Turbine compartment â⬠¢ Aft compartment â⬠¢ Generator Enclosure â⬠¢ 2 X 100 % Roof mounted centrifugal fans â⬠¢ Auto change over â⬠¢ Fan outlet gravity dampers, CO2 dampers and silencers provided â⬠¢ Enclosure Air inlet hoods with filter panels â⬠¢ Slow cool down fan provided for Turbine compartment Fan sizing Accessory compartment Heat load criteria: â⬠¢ Q = Heat Rejection = 104000 (BTU/Hr) = 436. 8 ( Kcal/min) â⬠¢ Design compartment temp ââ¬â 600 C at ambient of 430 C â⬠¢ Fan provided : 2 x 10,000 CFM at 3. 5 inch WC static pressure â⬠¢ The calculated temp raise with selected air flow 7. We will write a custom essay sample on Gas Turbine or any similar topic only for you Order Now 80 C â⬠¢ Static Pressure selected considering drop across suction filter, inlet, exit, silencer and ducting Number of air changes criteria: â⬠¢ Volume Of the Acc Comp = 278 m3 â⬠¢ Number of Air change/Hr = 60 (Meets NFPA and DEP 31. 29. 70. 31 requirements) Fan sizing Turbine compartment Heat load criteria: â⬠¢ Q = Heat Rejection = 1273469 (BTU/Hr) = 5348 ( Kcal/min) â⬠¢ Design compartment temp ââ¬â 1200 C at ambient of 430 C â⬠¢ Fan provided : 2 x 26,000 CFM at 3. 5 inch WC static pressure â⬠¢ The calculated temp raise with selected air flow 300 C â⬠¢ Static Pressure selected considering drop across suction filter, inlet, exit, silencer and ducting Number of air changes criteria: â⬠¢ Volume Of the Acc Comp = 215 m3 â⬠¢ Number of Air change/Hr = 185 (Meets NFPA and DEP 31. 29. 70. 31 requirements) Vent Fan Drawing Typical Accessory Compartment Fan Curve â⬠¢ Fan BHP : 5. 53 kw â⬠¢ Motor selected- 8 kw â⬠¢ Motor Data: â⬠¢ 4pole ââ¬â 415V,3Ph TEFC â⬠¢ Motor ambient Temp. 650 C â⬠¢ Insulation class ââ¬â H ( Temp raise limited to class B) â⬠¢ Flame proof NEC Class 1 Div 2 Gr CD Turbine Compartment Fan Curve â⬠¢ Fan BHP : 15. 45 kw â⬠¢ Motor selected- 19 kw â⬠¢ Motor Data: â⬠¢ 4pole ââ¬â 415V,3Ph TEFC â⬠¢ Motor ambient Temp. 650 C â⬠¢ Insulation class ââ¬â H ( Temp raise limited to class B) â⬠¢ Flame proof NEC Class 1 Div 2 Gr CD Exhaust Frame Blower (Fr6) â⬠¢ â⬠¢ â⬠¢ â⬠¢ â⬠¢ Two motor driven centrifugal Blowers Inlet screen silencer Air to turbine shell, exhaust frame via strut passages (Annular space) Flow:2470 CFM with two fans in operation Emergency:1860 CFM with one fan in operation Motor rating :50HP GT Auxiliaries GT Auxiliaries EXHAUST FRAME BLOWERS EXHAUST FRAME BLOWER GT Auxiliarie s MIST ELIMINATOR Removes oil mist entrained in the LO vapor ââ¬â Flow rate ðŸË⢠SCFM ââ¬â Demister pads(8Noââ¬â¢s)-SS316 wire mesh ââ¬â Coalescing filter element(99. 97% for droplets and particles 0. micron and larger) ââ¬â Outlet oil content not more than 5ppm by weight ââ¬â Centrifugal blowers (2 Noââ¬â¢s) and motors(11kw each) OUT LET FILTER CASING INLET BLOWER MOTOR GT Auxiliaries GT Auxiliaries MIST ELIMINATOR ââ¬â High speed rotating machinery: High temperature and shearing action in bearings generates a large volume of very fine oil mist (droplets) plus a considerable amount of vapor ââ¬â Oil mist and oil vapor is vented from the lube oil tank, it causes a visible plume ââ¬â Stringent environmental laws and regulations at all government levels ââ¬â Coalescers combine small aerosols through the filter media to form large droplets. How to cite Gas Turbine, Papers
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.